Configure settings for the Inline Pair Link Speed test
For the tester to run Inline Pair Link Speed tests, configure the available settings.
For more details about the product and how to configure features, click Help or press F1.
Steps
Inline Pair Link Speed Test Properties dialog box
Use this dialog box to check whether the network settings (speed/duplex) match on the two ports that form the inline pair and can force both ports to use the same settings.
Option | Definition |
---|---|
Name | The name of the test. If you want to run more than one instance of the same test type with different parameters, give each test a unique name. |
Node
(Clusters only) |
Select whether to run the test on ALL nodes or only on a specific node. |
States to Test | Select one or more Engine states in which to run the test.
|
Test Interval | Specify how frequently the test is run. The minimum interval is one second and the maximum is 86400 (one day). We recommend a minimum interval of four seconds. Running a test too frequently can increase overhead. |
Test Timeout | Enter the timeout in milliseconds. If the test being run does not return a response in the specified time, the test has failed. Avoid overly short timeout values. We recommend a timeout of 500–1000 ms, depending on the test. |
Failure section | |
Action | Select the action taken if a test fails.
|
Send Alert | When selected, sends an alert to notify administrators that a test has failed. |
Send SNMP Trap | When selected, sends an SNMP Trap. |