Disable DiagClient GUI output

The DiagClient troubleshooting tool allows a customer to remotely view logs and system data using a graphical user interface (GUI).

This exchange is unauthenticated and provides a potential vector by which this data may be exposed to outside sources when the output is sent back to the GUI.

Avoid this problem by removing the DiagClient GUI from the list of logging output destinations.

Steps

  1. Navigate to the bin directory \Websense\Web Security\bin and locate diagnostics.cfg.
    1. Open the file in a text editor and locate the following line:

      log4j.rootLogger=ALL, GUI, CONSOLE, FILE

    2. Remove GUI from the line.

      log4j.rootLogger=ALL, CONSOLE, FILE

  2. Run WebsenseAdmin –restart to restart Web services.

    Repeat these steps on each machine on which a web security solution component has been installed.

    With these settings, output will be sent only to the system console and log files. No output will be sent to the DiagClient GUI.