Bypass traffic on overload on Single Engines
You can configure the Single Engine to bypass traffic when the traffic load becomes too high.
By default, Single Engines inspect all connections. If the traffic load is too high for the Single Engine to inspect all connections, the Single Engine can dynamically reduce the number of inspected connections. This reduction can improve performance in evaluation environments, but some traffic might pass through without any access control or inspection.
CAUTION:
Using bypass mode requires a fail-open network interface card. If the ports that represent the interfaces cannot fail
open, policy installation fails on the engine. Bypass mode is not compatible with VLAN retagging. In network environments where VLAN
retagging is used, normal mode is automatically enforced.