Integrating with a third-party SIEM solution

Use the Settings > General > SIEM Integration page to configure web protection software to send log data from Filtering Service to a supported Security Information and Event Management (SIEM) solution. Audit Log entries can also be forwarded to a SIEM solution.

Before using this page to enable SIEM integration, make sure an instance of Multiplexer is installed for each Policy Server in your deployment.

In the Internet Activity Log Data section:

Steps

  1. Click Add to open a new window where you will continue configuring your SIEM integration.
  2. Provide the IP address or hostname of the machine hosting the SIEM product, as well as the communication Port to use for sending SIEM data.
  3. Specify the Transport protocol (UDP or TCP) to use when sending data to the SIEM product.
  4. Select the SIEM format to use. This determines the syntax of the string used to pass log data to the integration.
    • The available formats are syslog/CEF (ArcSight), syslog/key-value pairs (Splunk and others), syslog/LEEF (QRadar), and Custom.
    • If you select Custom, a text box is displayed. Enter or paste the string that you want to use. Click View SIEM format strings for a set of sample strings to use as a reference or template.
    • If you select a non-custom option, a sample Format string showing fields and value keys is displayed.
  5. Click OK to cache your changes. Changes are not implemented until you click Save and Deploy.

    When you save your changes, log data is distributed to both Log Server and the selected SIEM integration.

    Note that although the same data is passed from Filtering Service to both Log Server and the SIEM product, Log Server may be configured to perform data reduction processing tasks (like recording visits instead of hits, or consolidating log records). Because the SIEM product does not perform these data reduction tasks, there may be more SIEM entries than records in the Log Database.